Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 50,000pcs/year |
Delivery Time | 1-30 days |
Packaging Details | export package Woonden case or plastic film |
Compressor | Copeland/Danfoss/Panasonic/Daikin |
High Light | CE Air Source Heat Pumps, 32kW Air Source Heat Pumps, 5-200kW air source hot water heater |
Type | air source air to water heat pump |
Application: | Heating/Cooling, Hot Water |
After-sale Service | Online technical support, Onsite Installation, Onsite Training |
Noise | 38/40/42dB(A) |
Brand Name | LN/OEM |
Model Number | KCHR-8I/BP |
Certification | CB, CE, EMC, RoHS |
Place of Origin | China |
View Detail Information
Explore similar products
300KW Central Air Source Heat Pump With Stainless Steel Housing
R410A Air To Water Heating System Spray Coating DHW Heat Pump 300KW
Circulating Heat Industrial Air Source Chiller Heat Pump R407C
480V DHW Heat Pump Air Conditioning HVAC Heating System R407C
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 50,000pcs/year |
Delivery Time | 1-30 days | Packaging Details | export package Woonden case or plastic film |
Compressor | Copeland/Danfoss/Panasonic/Daikin | High Light | CE Air Source Heat Pumps, 32kW Air Source Heat Pumps, 5-200kW air source hot water heater |
Type | air source air to water heat pump | Application: | Heating/Cooling, Hot Water |
After-sale Service | Online technical support, Onsite Installation, Onsite Training | Noise | 38/40/42dB(A) |
Brand Name | LN/OEM | Model Number | KCHR-8I/BP |
Certification | CB, CE, EMC, RoHS | Place of Origin | China |
High Light | 38dBA DHW Heat Pump ,R32 Domestic DHW Heat Pump ,IPX4 inverter DHW Heat Pump |
This Air source heat pump is A floor heating and refrigeration with hot water module component system specifically solves the integration of refrigeration gas and floor heating equipment. It is one of the most stable solutions for floor heating and refrigeration at present.
Function:
floor heating;
summer air-conditioning;
Free hot water
Energy saving and comfort.
1.The principle of air source heat pump triple supply:
Air source heat pump triple supply unit is a kind of electric motor driven, vapor compression cycle, air as the heat source, can simultaneously supply cooling and domestic hot water, simultaneous heating and domestic hot water, separate cooling, separate heating, separate living Equipment for hot water. This equipment integrates heat pump air conditioning technology, heat pump water heater technology and advanced heat exchange technology to achieve the perfect combination of air conditioner and water heater.
1. Winter heating mode (domestic hot water is lower than the set temperature by 5℃, domestic hot water needs to be heated): Inverter compressor exhaust → domestic hot water heat exchanger → four-way valve switch to evaporator → expansion valve → Surface cooler (evaporator)→four-way valve→return to compressor for suction.
2. Winter heating mode (domestic hot water reaches the set temperature): compressor exhaust port→four-way valve→heating heat exchanger→expansion valve→surface cooler (evaporator)→four-way valve→return compressor suction gas.
3. Summer cooling mode (domestic hot water is lower than the set temperature by 5℃, domestic hot water needs heating): compressor exhaust → domestic hot water heat exchanger → four-way valve open → expansion valve → refrigeration heat exchanger → Four-way valve → return to the compressor for suction.
4. Summer cooling mode (domestic hot water reaches the set temperature): compressor exhaust → four-way valve → surface cooler (condenser) → expansion valve → refrigeration heat exchanger → four-way valve → return to compressor suction .
二,Performance comparison with other products
No. | performance | VRV multiple online | Air source heat pump air conditioner |
1 | Comfort | Using fluorine-containing chemicals as the refrigerant, the air outlet temperature is 3-7°C, a large amount of cold water will be generated, resulting in the indoor air being too dry, and the relative humidity will generally be lower than 25%; | Because water is used as the air-conditioning medium, the temperature of the air outlet of the fan is 13-15℃, and the relative humidity is 30%-45%, which effectively maintains the temperature environment; |
2 | Energy saving | The outdoor unit and the indoor unit together form a refrigeration system. When one indoor unit fails, the entire system will not work, causing the entire area to be unable to use the air conditioner. | The indoor unit is only a simple heat exchange function. The two are independent of each other and do not affect each other. The indoor unit or the outdoor unit can be maintained separately; multiple hosts are independently designed. If one system fails or has a problem, other systems can still be used |
3 | reliability | The outdoor unit and the indoor unit together form a refrigeration system. When one indoor unit fails, the entire system will not work, causing the entire area to be unable to use the air conditioner | The indoor unit is only a simple heat exchange function. The two are independent of each other and do not affect each other. The indoor unit or the outdoor unit can be maintained separately; multiple hosts are independently designed. If one system fails or has a problem, other systems can still be used. |
4 | Easy maintenance | Refrigerants are easy to leak. In order to find the leaks, leak detection is necessary. The damage to the decoration during the leak detection process is often greater than the impact of the leakage of the water system; The control system of the host and the internal machine requires matching, and it is not universal. After the product update, there is basically no internal machine matching the mainframe in the market. Later maintenance is complicated and expensive | Using water as the refrigerant carrier makes leakage easy to detect and convenient for maintenance as soon as possible. The internal unit of the air source heat pump adopts a fan coil unit, which is versatile and easy to replace. The fan coil unit is controlled by an independent indoor temperature control, and the high efficiency is simple. The air source heat pump is easy to maintain in the later period and the cost is low |
5 | safety | There are a wide range of refrigerant pipelines distributed indoors, leaking harmful gases to the human body, and open flames are required during maintenance to cause fire accidents | Low-pressure water system leakage is extremely unlikely, even if the leakage is very obvious, it is harmless to the human body; |
Strength of our heat pumps:
1.Full DC inverter floor heating air conditioner adopts inverter compressor dedicated for heat pump, and the noise is less than 50 decibels
2.The full DC frequency conversion floor heating air-conditioner adopts the linkage control of the internal and external units. The main unit and the thermostat have 485 remote, which can be remotely controlled. If there is an area air conditioner and floor heating, it can be viewed and turned off remotely.
3.The full DC frequency conversion floor heating air conditioner adopts a secondary system design, using the unit circulating pump and the end circulating pump respectively. The unit circulating pump and the end circulating pump adopt self-frequency conversion control. When the use area is small, the water pump runs at low frequency, which can greatly reduce the water pump. Energy loss
4.air-source heat pump triple-supply unit can adopt heat recovery method to produce hot water for free when the air-conditioning host is cooling
Service: OEM/ODM
Item | KCHR-8I/BP Side wind | KCHR-13I/BP Side wind) | KCHR-15I/BP Side wind | KCHR-15II/BP (Out of the wind) | |
Rated voltage | 220V~50Hz | 220V~50Hz | 220V~50Hz | 380V 3N~50Hz | |
Cooling and heating | Nominal cooling capacity | 7.8kW(2kW-9kW) | 13kW(3kW-15kW) | 14.5kW(4kW-16.5kW) | 14.5kW(4kW-16.5kW) |
Nominal cooling power consumption | 2.77KW | 4.6KW | 5.27KW | 5.27KW | |
Nominal cooling(COP) | 2.81 | 2.82 | 2.75 | 2.75 | |
IPLV | 4.11 | 4.13 | 4.02 | 4.02 | |
Nominal heating capacity | 8.4kW(2.5kW-9.6kW) | 14kW(3.5kW-16kW) | 17kW(4.3kW-18.5kW) | 17kW(2.5kW-18.5kW) | |
Nominal heating power consumption | 2.78KW | 4.5KW | 5.6KW | 5.6KW | |
Heating | Nominal heating capacity | 6.8KW | 10.5KW | 13KW | 13KW |
Nominal heating power consumption | 1.75KW | 2.65KW | 3.3KW | 3.3KW | |
Nominal heating(COP) | 3.88 | 3.96 | 3.93 | 3.93 | |
Maximum operating current | 20A | 33A | 41A | 21A | |
Maximum power consumption | 4KW | 6.6KW | 7.9KW | 7.9KW | |
Rated water flow | 1.34m²/h | 2.24m²/h | 2.5m²/h | 2.5m²/h | |
Refrigerant/charge volume | R410A/1750g | R410A/4000g | R410A/4000g | R410A/4800g | |
noise | ≤54dB(A) | ≤56dB(A) | ≤57dB(A) | ≤58dB(A) | |
Water resistance | ≤14kPa | ≤15kPa | ≤21kPa | ≤21kPa | |
Maximum working pressure on low pressure/high pressure side | 4.5Mpa/0.15Mpa | 4.5Mpa/0.15Mpa | 4.5Mpa/0.15Mpa | 4.5Mpa/0.15Mpa | |
Allowable working pressure on suction/exhaust side | 4.5Mpa/0.15Mpa | 4.5Mpa/0.15Mpa | 4.5Mpa/0.15Mpa | 4.5Mpa/0.15Mpa | |
Anti-shock level | I | I | I | I | |
waterproof level | IPX4 | IPX4 | IPX4 | IPX4 | |
Unit size (l× w × h) | 1030×410×865(mm) | 1030×410×1390(mm) | 1030×410×1390(mm) | 820×780×1700(mm) | |
(Cold and warm) Caliber of inlet and outlet | DN25 | DN32 | DN32 | DN32 | |
(Hot water) Caliber | DN20 | DN25 | DN25 | DN25 | |
Application area | 60㎡ | 100㎡ | 110㎡ | 110㎡ | |
Nominal refrigeration conditions: ambient dry bulb 35℃, outlet temperature 7℃. Nominal heating conditions: ambient dry bulb 7℃, ambient wet bulb 6℃, outlet temperature 45℃ | |||||
Nominal hot water production conditions: ambient dry bulb 20℃, ambient wet bulb 15℃, initial water temperature 15℃, end water temperature 55℃. |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
1.MILLION-2MILLION
Employee Number:
50~150
Ecer Certification:
Active Member
As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ... As one of the most well-known and respected brands in the ASHP market, our heat pumps are suitable for small retail outlets and commercial buildings as well as domestic properties. Using efficient heat pump technology to deliver supreme comfort and low operating costs, we have different series ...
Get in touch with us
Leave a Message, we will call you back quickly!