China factories

China factory - Henan Lantian Medical Supplies Co.,Ltd.

Henan Lantian Medical Supplies Co.,Ltd.

  • China,Zhengzhou ,Henan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Sodium Azide COVID-19 Test Kit Lateral Flow Test Kits With Sample Buffer
China Sodium Azide COVID-19 Test Kit Lateral Flow Test Kits With Sample Buffer

  1. China Sodium Azide COVID-19 Test Kit Lateral Flow Test Kits With Sample Buffer

Sodium Azide COVID-19 Test Kit Lateral Flow Test Kits With Sample Buffer

  1. MOQ: To be negotiated
  2. Price: To be negotiated
  3. Get Latest Price
Supply Ability 10000 Kit/Kit per Day
Delivery Time To be negotiated
Packaging Details Kit
Product Name COVID-19 Test Kit Lateral Flow Test Kits Product
Certificate CE BfArm
Packing Specification 1 test/kit, 5 tests/kit, 10 tests/kit, 20 tests/kit, 25 tests/kit, 50 tests/kit, 100 tests/kit.
Sample buffer Phosphate, sodium azide, etc
Composition Test card, sample buffer and swab
validity period It was kept at 2 ℃ to 30 ℃ for 18 months
Validity of aluminum foil bag An hour
Brand Name ZOSBIO
Model Number 2019-NCoV Ag Rapid Test
Certification CE BfArm
Place of Origin Henan,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10000 Kit/Kit per Day Delivery Time To be negotiated
Packaging Details Kit Product Name COVID-19 Test Kit Lateral Flow Test Kits Product
Certificate CE BfArm Packing Specification 1 test/kit, 5 tests/kit, 10 tests/kit, 20 tests/kit, 25 tests/kit, 50 tests/kit, 100 tests/kit.
Sample buffer Phosphate, sodium azide, etc Composition Test card, sample buffer and swab
validity period It was kept at 2 ℃ to 30 ℃ for 18 months Validity of aluminum foil bag An hour
Brand Name ZOSBIO Model Number 2019-NCoV Ag Rapid Test
Certification CE BfArm Place of Origin Henan,China
High Light aluminum foil COVID-19 Test KitCOVID-19 rapid Test Kit with sample buffersodium azide Lateral Flow Test Kits

COVID-19 Test Kit Lateral Flow Test Kits Product

 

Intended Use


The kit was used for qualitative detection of 2019 ncovag and was collected from human nasal swab samples.
2019-ncov is a new type of ncov. It can cause viral pneumonia. The main clinical symptoms are fever, fatigue and dry cough. Some patients develop nasal congestion, runny nose, sore throat, diarrhea and other symptoms. Severe cases usually develop dyspnea and / or hypoxemia after one week. Severe cases quickly develop into acute respiratory distress syndrome, septic shock, difficult to correct metabolic acidosis and coagulation dysfunction.
The product was qualitatively tested on 2019 ncovag suspicious nasal swab samples by nasal chromatography. In the acute phase of infection, the antigen is usually detected in nasal swab samples. Positive results indicate the presence of viral antigens, but the clinical relevance of the patient's medical records and other diagnostic information is also needed to determine the infection status. Positive results do not exclude bacterial infection or mixed infection with other viruses.
This kit is used in the homes of laymen in environments outside the laboratory (such as human homes, offices, sports activities, airports, schools and other specific non-traditional places). The test results of this kit are only for clinical reference. It is suggested to conduct a comprehensive analysis of the condition according to the patient's clinical manifestations and other clinical examinations.

Principle of Detection


This kit is based on the principle of double antibody sandwich technology. The 2019ncov monoclonal antibody labeled with the marker is sprayed on the binding pad as an indicator marker. During the test, it was combined with 2019ncov monoclonal antibody labeled 2019ncov - Ag in the sample to form Ag AB complex. The complex moves upward through the capillary effect to form a sandwich complex until it is captured by another pre grouping of 2019 ncov monoclonal antibody on the test line. A red band will appear in the T area of the 2019ncov Ag interpretation window of the sample. If not, it is the result of negation. The control line (c) is used for program control. If the test program runs correctly, it should always be displayed.

 

Main Components


The kit is composed of test card, sample bag and cotton swab.
Test card: it is composed of aluminum foil packaging, desiccant, test strip and plastic card. The test paper is composed of absorbent paper, nitrocellulose film, sample pad, bonding pad and rubber plate. Nitrocellulose film T-line (test line) is packaged as 2019ncov AB and c-line (QC line), which are wrapped with Goat anti infective antibody and 2019ncovab label binding pad.
Sample buffer: phosphoric acid, sodium nitride, etc.

Storage Conditions and Validity


 

It is effective for 18 months at 2 ℃ ~ 30 ℃.
Aluminum foil unpacking is valid for 1 hour.
Production batch number: see the label for details.
Validity period: see the label for details.

Sample Requirements


(1)Nasal swab collection method: insert the sampling swab into the nostril and insert the swab piece 2.5cm from the edge of the nostril. The cotton swab rotates five times along the nasal mucosa, and then repeat the process with the same cotton swab for the other nostrils (see Figure 1).

Figure 1 Collection method for nasal swab

 

(2) Sample processing: the collected samples are provided as this kit. They are processed as soon as possible (if not immediately, they are kept in sealed containers after drying and sterilization) and kept within 2 hours and 24 hours. Keep it at - 70 ℃ (but avoid repeated thawing and freezing)

Test Method


Please read the instructions carefully before testing. Restore all reagents to room temperature before testing. The test must be carried out at room temperature.

1. sample processing (see Figure 2)

1. inserts the sample swab into the sample buffer and rotates near the inner wall for about 10 times to dissolve the sample in the solution as much as possible.

2. squeezes the swab tip along the inner wall of the tube to flow as much liquid as possible into the tube, remove and discard the swab.

3. Cover with the drops.

  
           Figure 2 Sample processing             

   

 

Figure 3 Detection procedure

 

2. Test procedure (see Figure 3)

1. took out the exam card.

The 2. adds 2 drops (about 80 μ50) extracts the processed sample into the loading hole of the test card and then activates the timer.

3. read the results after 15 minutes at room temperature. Invalid results after 20 minutes.

 

Interpretation of Test Results


Description of the test card (Figure 4):
Invalid ① result: Quality Control Line (C Line) no response line is invalid and should be redetected.
② negative result: Quality control line (C) is red ribbon.
③ positive results: two red bands, test (T) and mass control (C).

 

Figure 4 Interpretation of test results

 

Limitation of test method


1. This product is used for qualitative test and only for invitro diagnosis.
2. This product is suitable for nasal swab samples. The results of other sample types may be incorrect or invalid.
3. In order to test, it is necessary to add an appropriate number of samples. Too large or too small sample size may produce inaccurate results.
4. The test results of this reagent are only for clinical reference and should not be used as the only basis for clinical diagnosis and treatment. The final diagnosis can only be made after a comprehensive evaluation of all clinical and examination results.

Product Performance Indicators


1. test limit: when inactivated New Coronavirus was incubated, the minimum test limit of the kit was 6. × 102tcid50 / mL.
2. Use the company's reference products for testing, and the results must meet the requirements of the company's reference products.
2.1 recognition rate of positive quality management products: all p1-p5 positive quality management products are positive.
2.2 recognition rate of negative control products: all negative control products N1 ~ N10 are negative.
2.3 detection limit: the minimum detection limit refers to products L1-L3, and the negative and positive L2 and L3 of L1.
2.4 reproducibility: J1 and J2, 10 times at a time.
3. Cross reactivity: in order to evaluate the potential interference to the 2019 ncov Ag test plan, the following concentrations of microorganisms and viruses were added to the sample at the specified concentration. The results showed that there was no cross reaction and no interference of various microorganisms and viruses.

 

 

SN Microorganisms Concentration Cross reaction
1 Coronavirus (HKU1, OC43, NL63 and 229E) 1.0×105TCID50/mL No
2 H1N1 influenza (new type A H1N1 influenza virus (2009), seasonal H1N1 influenza virus), H3N2, H5N1, H7N9 1.0×105TCID50/mL No
3 Influenza B (Yamagata strain, Victoria strain) 2.5×105TCID50/mL No
4 Respiratory syncytial virus 2.8×105TCID50/mL No
5 Group A, B, C of rhinovirus 2.0×105TCID50/mL No
6 Type 1, 2, 3, 4, 5, 7, 55 of adenovirus 2.0×105TCID50/mL No
7 Group A, B, C and D of enterovirus 2.0×105TCID50/mL No
8 EB virus 2.0×105TCID50/mL No
9 Measles virus 2.0×105TCID50/mL No
10 Human cytomegalovirus 2.0×105TCID50/mL No
11 Rotavirus 2.0×105TCID50/mL No
12 Norovirus 2.0×105TCID50/mL No
13 Mumps virus 2.0×105TCID50/mL No
14 Varicella-zoster virus 2.0×105TCID50/mL No
15 Mycoplasma pneumoniae 1.0×106CFU/mL No
16 Legionella pneumophila 1.0×106CFU/mL No
17 Haemophilus influenzae 1.0×106CFU/mL No
18 Streptococcus pyogenes (group A) 1.0×106CFU/mL No
19 Streptococcus pneumoniae 1.0×106CFU/mL No
20 Escherichia Coli 1.0×106CFU/mL No
21 Pseudomonas aeruginosa 1.0×106CFU/mL No
22 Neisseria meningitidis 1.0×106CFU/mL No
23 Candida albicans 1.0×106CFU/mL No
24 Staphylococcus aureus 1.0×106CFU/mL No

 

 

4.Interference: the 2019ncov - Ag test plan adds the following concentrations to the sample at the specified concentrations to evaluate potential interference. The results showed that all drugs did not interfere with the test results of the reagent.

 

 

 

Interfering substances Concentration Interfering substances Concentration
Mucoprotein 1mg/mL Ribavirin 0.4mg/mL
Whole Blood 1% Fluticasone 0.5mg/mL
Oxymetazoline 10mg/mL Dexamethasone 5 mg/mL
Histamine hydrochloride 10mg/mL Triamcinolone acetonide 5mg /mL
Tobramycin 1mg/mL Levofloxacin 0.2 mg/mL
Oseltamivir 1mg/mL Azithromycin 0.1 mg/mL
Zanamivir 1mg/mL Ceftriaxone 0.4 mg/mL
Arbidol 0.5mg/mL Meropenem 0.2 mg/mL
 

                  

5. Hook effect: × 106tcid50 / ml, 2019ncov inactivated culture was not observed in the high concentration range of 1.0.
6. Clinical trial: nasal swab samples were evaluated using reverse transcription polymerase chain reaction test reagent as contrast agent. 120 positive samples were selected and 120 negative samples (RT-PCR test) were tested by Xiu reagent. The results are summarized as follows.

 

Nasal swab RT-PCR Sum
Positive Negative
Positive 116 2 118
Negative 4 118 122
Sum 120 120 240
Sensitivity 96.67%, (95%CI: 91.74%~98.70%)
Specificity 98.33%, (95%CI: 94.13%~99.54%)
 
 

Precautions


1. This product is only used for invitro diagnosis.
2.This product can only be used once and cannot be reused.
3. Please read the instructions carefully before operation and carry out the experimental operation in strict accordance with the reagent instructions.
4. Avoid experiments under harsh environmental conditions such as high concentration corrosive gas, dust, sodium hypochlorite, acid-base or acetaldehyde. The disinfection of the laboratory should be carried out after the experiment.

5. All samples and reagents used in the will be considered potentially infectious and handled in accordance with local regulations.
6. The period of validity shall be indicated on the package. The test card should be used as soon as possible after being removed from the aluminum foil bag to prevent moisture.

Logo interpretation


Do not re-use Store at 2℃~30℃
Consult instructions for use In vitro diagnostic medical devic
Batch code Use-by date
Keep dry Keep away from sunlight
Authorized representative in the European Community Manufacturer

 

 

Basic Information

 


 

ZHONGXIU SCIENCE AND TECHNOLOGY CO.,LTD

Dingluan industrial zone ,Changyuan City,453400,P.R.CHINA

Tel:+86-371-55016575

Email:zosbio@zosbio.com

Web:www.zosbio.com

SUNGO Europe B.V.

Olympisch Stadion 24, 1076DE Amsterdam, Netherlands

 

 

 

Company profile


 
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2016

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Lantian Medical Supplies Co.,Ltd.
  • Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.
  • https://www.agrapidtestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement