China factories

China factory - Henan Lantian Medical Supplies Co.,Ltd.

Henan Lantian Medical Supplies Co.,Ltd.

  • China,Zhengzhou ,Henan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32
China Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32

  1. China Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32
  2. China Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32
  3. China Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32
  4. China Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32

Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32

  1. MOQ: To be negotiated
  2. Price: To be negotiated
  3. Get Latest Price
Model Numbe S-3
Specifications 0.7X25、0.7X32、0.6X25、0.6X32、0.6X16、0.5X16
Production date see package
Expiration date see package
Name of manufacturer Henan Zhongxiu Medical Instrument Co., Ltd
contact information 0373-8969992
Brand Name Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions
Model Number S-3
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Model Numbe S-3 Specifications 0.7X25、0.7X32、0.6X25、0.6X32、0.6X16、0.5X16
Production date see package Expiration date see package
Name of manufacturer Henan Zhongxiu Medical Instrument Co., Ltd contact information 0373-8969992
Brand Name Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions Model Number S-3
Place of Origin China
High Light Disposable Arterial Blood Sample Collector0.7*32 Arterial Blood Sample Collector0.7*25 Arterial Blood Collector

Disposable Use Of Human Arterial Blood Samples Collector(S-3)


Structure Composition


Disposable human artery blood sample collector (hereinafter referred to as collector) S-3 is composed of a sample storage device, a pull rod, a piston, a piston breathable valve, a seal, a blood needle, a needle sheath, and a square plastic block. D-3 is composed of a sample storage device, a pull rod, a piston, a piston vent valve, a seal, a blood sampling needle, a needle sheath and a buckle sheath

 

 

Objective


  • Extracting arterial blood for blood gas analysis is the best way to objectively reflect the nature and degree of respiratory failure and judge whether there is anoxia and carbon dioxide retention
  • To guide the adjustment of parameters of oxygen therapy and mechanical ventilation
  • Arterial administration during first aid

 

Scope Of Application


It is suitable for the collection and storage of arterial blood samples. The collected blood samples can be used for blood gas analysis

 

 

Storage Of Specimens


  • The blood contains respirable active cells (white blood cells, reticulocytes), which continue to consume oxygen to produce CO 2 after sampling. Generally, arterial blood samples are stored at 37℃ in vitro, and PACO 2 increases by 1mmHg every 10min and pH decreases by 0.01. Therefore, the blood should be sent for examination immediately after drawing. Generally, the time from the collection of the sample to the completion of determination should not exceed 30min.
  • In case of special circumstances, it can not be determined immediately, it should be placed in a container containing ice water or in a refrigerator, but the storage time should not exceed 2h. Before the measurement should be placed at room temperature for a few minutes, because the temperature of every 1℃ can make the pH rise 0.014, PaO2, PaCO2 also has an impact

 

Usage Method


  1. The human artery was selected and the disposable human artery blood sample collector was taken out.
  2. Pull the pull rod to the position of blood volume for pre-collection;
  3. Remove the needle sheath, puncture the artery, arterial blood naturally gushes out;
  4. When the arterial blood reaches the preset position, the piston vent valve closes when wet, and the blood collector is pulled out.
  5. Activate the safety device (button up sheath or insert the needle into the cube plastic block to prevent accidental stab injury) and remove the needle;
  6. Screw the seal and leave it to be tested

 

Contraindication


  1. Anticoagulant therapy;
  2. Patients with severe peripheral vascular atherosclerosis;
  3. Patients suffering from coagulation disorders;
  4. Patients with a history of vasospasm after puncture;
  5. Samples should not be taken from areas of inflammation, purulent infection, sclerosis, scarring, or skin disease

 

Precautions, Warnings and Suggestive Instructions


  1. Disposable use and destruction after use;
  2. Do not use the contents if the container has been opened or damaged.
  3. The use of the product must comply with the requirements of the relevant operating codes and regulations of the medical department;
  4. In the process of using the product, it should be carried out slowly to avoid exerting too much force and causing pain to patients.
  5. Discard as infected waste after use.

Warning


  • Blood samples should be collected by medical personnel for the use of the product. Blood samples and blood collection equipment should be handled with caution. Please wear qualified rubber gloves to avoid direct contact with blood. Aseptic techniques should be adopted during the whole process of blood collection to prevent infection of the blood collection site.
  • If there are any bubbles in the collector, remove them immediately and seal the sampler with a seal.
  • Turn the collector upside down several times, and then roll it back and forth in the palm of your hand several times to ensure that the blood sample is well mixed.
  • Avoid storing blood samples or minimize storage time. If it is not possible to test immediately, please store it in a refrigerator at 4 ° C and test the blood sample within 30 minutes after collection

 

 

Company profile


ZOS-F2100(Multi-Channel) 4ZOS-F2100(Multi-Channel) 5ZOS-F2100(Multi-Channel) 6ZOS-F2100(Multi-Channel) 7

Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2016

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Lantian Medical Supplies Co.,Ltd.
  • Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.
  • https://www.agrapidtestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement