{"title":"Disposable Human Arterial Blood Sample Collector 0.7*25 0.7*32","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/68\/f6\/52bd16d47c16a794024d57f32990-200x200-1\/disposable_human_arterial_blood_sample_collector_0_7_2a25_0_7_2a32.jpg","attrs":{"Brand Name":"Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions","Model Number":"S-3","Place of Origin":"China","Minimum Order Quantity":"To be negotiated"}}
{"title":"0.6*16 0.5*16 Human Arterial Blood Sample Collector For Hospitals","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/14\/50\/d5622769c2a429b29709b5bcb736-200x200-1\/0_6_2a16_0_5_2a16_human_arterial_blood_sample_collector_for_hospitals.jpg","attrs":{"Brand Name":"Disposable Use Of Human Arterial Blood Samples Collector(S-3)","Certification":"","Place of Origin":"Henan, China","Model Number":"S-3"}}
{"title":"ZOSBIO Blood Sample Collector With Blood Extraction Needle aseptic S-3","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/87\/50\/04908e2321bd078335fd840ac700-200x200-1\/zosbio_blood_sample_collector_with_blood_extraction_needle_aseptic_s_3.jpg","attrs":{"Brand Name":"Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions","Model Number":"S-3","Place of Origin":"China","Minimum Order Quantity":"To be negotiated"}}
{"title":"Single Use Blood Sample Collector Sterile Blood Gas Analysis","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/60\/99\/b28140ce190a1dd34f973b92ee6e-200x200-1\/single_use_blood_sample_collector_sterile_blood_gas_analysis.jpg","attrs":{"Brand Name":"Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions","Model Number":"S-3","Place of Origin":"Henan","Minimum Order Quantity":"To be negotiated"}}
{"title":"Blood Sample Collector With Blood Extraction Needle Aseptic S-3 Storage Of","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/69\/78\/ac5facdb521060ca5dbf5a5259fe-200x200-1\/blood_sample_collector_with_blood_extraction_needle_aseptic_s_3_storage_of_specimens.jpg","attrs":{"Brand Name":"Blood Sample Collector With Blood Extraction Needle Aseptic S-3 Storage Of Specimens","Model Number":"S-3","Place of Origin":"China","Minimum Order Quantity":"To be negotiated"}}
{"title":"Blood Sample Collector With Blood Extraction Needle Aseptic S-3 Storage Of","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/69\/78\/ac5facdb521060ca5dbf5a5259fe-200x200-1\/blood_sample_collector_with_blood_extraction_needle_aseptic_s_3_storage_of_specimens.jpg","attrs":{"Brand Name":"Blood Sample Collector With Blood Extraction Needle Aseptic S-3 Storage Of Specimens","Model Number":"S-3","Place of Origin":"China","Minimum Order Quantity":"To be negotiated"}}
{"title":"0.6*16 0.5*16 Human Arterial Blood Sample Collector For Hospitals","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/14\/50\/d5622769c2a429b29709b5bcb736-200x200-1\/0_6_2a16_0_5_2a16_human_arterial_blood_sample_collector_for_hospitals.jpg","attrs":{"Brand Name":"Disposable Use Of Human Arterial Blood Samples Collector(S-3)","Certification":"","Place of Origin":"Henan, China","Model Number":"S-3"}}
Disposable Use Of Human Arterial Blood Samples Collector(S-3)
Structure Composition
Disposable human artery blood sample collector (hereinafter referred to as collector) S-3 is composed of a sample storage device, a pull rod, a piston, a piston breathable valve, a seal, a blood needle, a needle sheath, and a square plastic block. D-3 is composed of a sample storage device, a pull rod, a piston, a piston vent valve, a seal, a blood sampling needle, a needle sheath and a buckle sheath
Objective
Extracting arterial blood for blood gas analysis is the best way to objectively reflect the nature and degree of respiratory failure and judge whether there is anoxia and carbon dioxide retention
To guide the adjustment of parameters of oxygen therapy and mechanical ventilation
Arterial administration during first aid
Scope Of Application
It is suitable for the collection and storage of arterial blood samples. The collected blood samples can be used for blood gas analysis
Storage Of Specimens
The blood contains respirable active cells (white blood cells, reticulocytes), which continue to consume oxygen to produce CO 2 after sampling. Generally, arterial blood samples are stored at 37℃ in vitro, and PACO 2 increases by 1mmHg every 10min and pH decreases by 0.01. Therefore, the blood should be sent for examination immediately after drawing. Generally, the time from the collection of the sample to the completion of determination should not exceed 30min.
In case of special circumstances, it can not be determined immediately, it should be placed in a container containing ice water or in a refrigerator, but the storage time should not exceed 2h. Before the measurement should be placed at room temperature for a few minutes, because the temperature of every 1℃ can make the pH rise 0.014, PaO2, PaCO2 also has an impact
Usage Method
The human artery was selected and the disposable human artery blood sample collector was taken out.
Pull the pull rod to the position of blood volume for pre-collection;
Remove the needle sheath, puncture the artery, arterial blood naturally gushes out;
When the arterial blood reaches the preset position, the piston vent valve closes when wet, and the blood collector is pulled out.
Activate the safety device (button up sheath or insert the needle into the cube plastic block to prevent accidental stab injury) and remove the needle;
Screw the seal and leave it to be tested
Contraindication
Anticoagulant therapy;
Patients with severe peripheral vascular atherosclerosis;
Patients suffering from coagulation disorders;
Patients with a history of vasospasm after puncture;
Samples should not be taken from areas of inflammation, purulent infection, sclerosis, scarring, or skin disease
Precautions, Warnings and Suggestive Instructions
Disposable use and destruction after use;
Do not use the contents if the container has been opened or damaged.
The use of the product must comply with the requirements of the relevant operating codes and regulations of the medical department;
In the process of using the product, it should be carried out slowly to avoid exerting too much force and causing pain to patients.
Discard as infected waste after use.
Warning
Blood samples should be collected by medical personnel for the use of the product. Blood samples and blood collection equipment should be handled with caution. Please wear qualified rubber gloves to avoid direct contact with blood. Aseptic techniques should be adopted during the whole process of blood collection to prevent infection of the blood collection site.
If there are any bubbles in the collector, remove them immediately and seal the sampler with a seal.
Turn the collector upside down several times, and then roll it back and forth in the palm of your hand several times to ensure that the blood sample is well mixed.
Avoid storing blood samples or minimize storage time. If it is not possible to test immediately, please store it in a refrigerator at 4 ° C and test the blood sample within 30 minutes after collection
Company profile
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments. The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2016
Employee Number:
500~1000
Ecer Certification:
Active Member
Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...