China Single Use Blood Sample Collector Sterile Blood Gas Analysis
China Single Use Blood Sample Collector Sterile Blood Gas Analysis

  1. China Single Use Blood Sample Collector Sterile Blood Gas Analysis
  2. China Single Use Blood Sample Collector Sterile Blood Gas Analysis
  3. China Single Use Blood Sample Collector Sterile Blood Gas Analysis
  4. China Single Use Blood Sample Collector Sterile Blood Gas Analysis

Single Use Blood Sample Collector Sterile Blood Gas Analysis

  1. MOQ: To be negotiated
  2. Price: To be negotiated
  3. Get Latest Price
Model Numbe S-3
Specifications 0.7X25、0.7X32、0.6X25、0.6X32、0.6X16、0.5X16
Production date see package
Expiration date see package
Name of manufacturer Henan Zhongxiu Medical Instrument Co., Ltd
contact information 0373-8969992
Brand Name Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions
Model Number S-3
Place of Origin Henan

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Model Numbe S-3 Specifications 0.7X25、0.7X32、0.6X25、0.6X32、0.6X16、0.5X16
Production date see package Expiration date see package
Name of manufacturer Henan Zhongxiu Medical Instrument Co., Ltd contact information 0373-8969992
Brand Name Disposable Use Of Human Arterial Blood Samples Collector(S-3) Precautions, Warnings And Suggestive Instructions Model Number S-3
Place of Origin Henan
High Light Blood Sample Collector Blood Gas AnalysisSingle Use Blood Sample CollectorSingle Use sterile blood gas needle

Disposable Use Of Human Arterial Blood Samples Collector(S-3)


Structure composition


The disposable human arterial blood sample collector (hereinafter referred to as the collector) S-3 is composed of a sample container, a pull rod, a piston, a piston breather valve, a seal, a blood sampling needle, a needle sheath, and a cubic plastic block. D-3 is composed of sample container, pull rod, piston, piston breather valve, seal, blood collection needle, needle sheath, and button sheath.

 

 

Objective


  • Taking arterial blood for blood gas analysis is the best way to objectively reflect the nature and degree of respiratory failure, and to judge whether there is hypoxia and carbon dioxide retention
  • Guide the adjustment of various parameters of oxygen therapy and mechanical ventilation
  • Arterial administration in emergency

 

Scope of application


Suitable for the collection and storage of arterial blood samples, and the blood gas analysis of the collected blood samples

 

 

 

Storage of specimens


  • The blood contains active respirable cells (white blood cells, reticulocytes), which continue to consume oxygen to produce CO 2 after sampling. Generally, arterial blood samples are stored in vitro at 37°C. PaCO 2 increases by 1mmHg every 10 minutes and pH decreases by 0.01. Therefore, the blood should be sent for examination immediately after the blood is drawn. Generally, the time from the collection of the specimen to the completion of the determination should not exceed 30 minutes.
  • In case of special circumstances that cannot be measured immediately, it should be placed in a container containing ice water or in a refrigerator, but the storage time should not exceed 2 hours. Place it at room temperature for a few minutes before the measurement, because every 1°C drop in temperature can increase the pH by 0.014, which also affects PaO2 and PaCO2.

 

usage method


  1. Select the human artery and take out the disposable human arterial blood sample collector;
  2. Pull the lever to the pre-collection volume position;
  3. Remove the needle sheath, puncture the artery, arterial blood will gush out naturally;
  4. When the arterial blood reaches the preset position, the piston vent valve is closed when wet, and the blood sampling device is pulled out;
  5. Activate the safety device (buckle the button sheath or insert the needle into the cubic plastic block to prevent accidental stabbing), and remove the needle;
  6. Screw on the seal to seal it and leave it for testing.

 

contraindication


  1. Anticoagulant therapy;
  2. Patients with severe peripheral atherosclerosis;
  3. Patients with coagulopathy;
  4. Patients with a history of vasospasm after puncture;
  5. Do not sample from areas with inflammation, purulent infection, induration, scars, and skin diseases.

 

Precautions, warnings and suggestive instructions


  1. One-time use, destroy after use;
  2. If the packaging container has been opened or damaged, it is prohibited to use the contents;
  3. The use of the product must comply with the requirements of the relevant operating specifications and relevant regulations of the medical department;
  4. During the use of the product, it should be carried out slowly to avoid excessive force, which may cause pain to the patient;
  5. After use, discard it as infected waste.

warning


  • When using the product, medical personnel should collect blood samples, and handle blood samples and blood collection equipment carefully. Please wear qualified rubber gloves to avoid direct blood contact. During the whole blood collection process, please adopt aseptic technique to prevent infection of the blood collection site.
  • If there are bubbles in the collector, remove them immediately and seal the sample container with a seal.
  • Turn the collector upside down several times, and then roll it back and forth in the palm of your hand several times to ensure that the blood sample is well mixed.
  • Avoid storing blood samples, or minimize storage time. If it is not possible to test immediately, please store it in a refrigerator at 4°C, and test the blood sample within 30 minutes after collection

 

 

Company profile


ZOS-F2100(Multi-Channel) 4ZOS-F2100(Multi-Channel) 5ZOS-F2100(Multi-Channel) 6ZOS-F2100(Multi-Channel) 7

Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2016

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Lantian Medical Supplies Co.,Ltd.
  • Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.
  • https://www.agrapidtestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement