China 15 Minutes Antibody Fast Detection Kit 98.33% Specificity
China 15 Minutes Antibody Fast Detection Kit 98.33% Specificity

  1. China 15 Minutes Antibody Fast Detection Kit 98.33% Specificity
  2. China 15 Minutes Antibody Fast Detection Kit 98.33% Specificity

15 Minutes Antibody Fast Detection Kit 98.33% Specificity

  1. MOQ: To be negotiated
  2. Price: To be negotiated
  3. Get Latest Price
Supply Ability 10000 Kit/Kit per Day
Delivery Time To be negotiated
Packaging Details Kit
Product Name 2019-nCoV Ag Rapid Test (Immunochromatography)
Certificate CE BfArm
Packing Specification 1 test/kit, 5 tests/kit, 10 tests/kit, 20 tests/kit, 25 tests/kit, 50 tests/kit, 100 tests/kit.
Sample buffer Phosphate, sodium azide, etc
Composition Test card, sample buffer and swab
validity period It was kept at 2 ℃ to 30 ℃ for 18 months
Validity of aluminum foil bag An hour
Brand Name ZOSBIO
Model Number 2019-NCoV Ag Rapid Test
Certification CE BfArm
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10000 Kit/Kit per Day Delivery Time To be negotiated
Packaging Details Kit Product Name 2019-nCoV Ag Rapid Test (Immunochromatography)
Certificate CE BfArm Packing Specification 1 test/kit, 5 tests/kit, 10 tests/kit, 20 tests/kit, 25 tests/kit, 50 tests/kit, 100 tests/kit.
Sample buffer Phosphate, sodium azide, etc Composition Test card, sample buffer and swab
validity period It was kept at 2 ℃ to 30 ℃ for 18 months Validity of aluminum foil bag An hour
Brand Name ZOSBIO Model Number 2019-NCoV Ag Rapid Test
Certification CE BfArm Place of Origin China
High Light 15 Minutes Antibody Fast Detection KitAntibody Fast Detection Kit 98.33% Specificity98.33% Specificity antibody rapid test kits

2019-NCoV Ag Rapid Test (Immunochromatography) Usage Manual For Self-Test Interpretation Of Test Results

Intended Use


Kkit are used for qualitative detection of ncov ag. collected from nasal exchange specimens
As a new weapon, the 2019 NCOV is a new weapon that can cause β-viral pneumonia, the main clinical symptoms are fever, fatigue and dry cough. Many patients have nasal congestion, runny nose, sore throat, diarrhea or other symptoms. Critical patients usually develop dyspnea or hypoxemia after a week. Severe cases quickly developed into acute respiratory distress syndrome, septic shock, refractory metabolic acidosis, coagulopathy disorder.
The ncovag of 2019 in the suspected patient was detected by lateral immune examination. In the nasal test, the antigen was detected. The positive results showed the presence of viral antigen, but the clinical correlation between the patient's history and other diagnostic information is also necessary to determine the infection status. The positive results could not exclude bacterial infection or co-infection with other viruses.
The kit is used by Reemen in a non-resident environment (e. g. private homes and offices, physical activities, airports, and schools). The test results of this kit are available for clinical reference only. A comprehensive analysis through clinical symptoms and other tests.

Principle of Detection


The kit is an immunoassay kit based on the principle of dual antibody sandwich technology. The ncov monoclonal antibody of 2019 labeled as labeled on the binding pad. In the test procedure, Combined to the ag 19 cov monoclonal antibody of 2019 ncov ag in the labeled test material, The ag―ab complex was captured by another 2019 ncov monoclonal antibody, Moving upward through the capillary effect, Until the sandwich complex is formed. If the NCO VAG of 2019 exists in the sample, The red band appears in the T area of the explanation window. Otherwise, The result is negative. The Control Line (C) is used for program control. If the test program runs successfully, It must always be displayed.

 

Main Components


The kit consists of test cards, sample buffer, and SWAB.
Test card: composed of aluminum foil bag, desiccant, test strip and plastic card. Test sheet consists of absorbent paper, nitrocellulose film, test pad, adhesive pad and rubber sheet. t line covering nitrocellulose film with 2019 nvvab (test line), c with goat-mouse polyclonal ab (quality management line) and 2019 nvvab. on the pad
Sample buffer: phosphate, sodium nitride, etc.

Storage Conditions and Validity


 

Keep it at 2℃~30℃, and the validity period is tentatively set at 18 months.

Aluminum foil bag is valid for 1 hour.
Production lot number: See: Details Label.
For more information, see talabel.

 

Sample Requirements


(1) Snose collection: insert the sample swab into the nasal cavity and the tip 2.5 cm from the edge of the nasal cavity. Roll the swab along the inner nasal mucosa 5 times and repeat the process with the same swab (see Figure 1)

Figure 1 Collection method for nasal swab

 

(2) Sample Treatment: The recycled samples shall be treated as soon as possible with the sample buffer solution provided as this box (should not be treated immediately, they shall be stored in dried, sterilized and sealed containers) -70 stored within 2 hours ℃ (but avoid repeated freezing and thawing)

Test Method


Read the instructions carefully before testing. Test all reagents to room temperature. Test at room temperature.
(1) Test material treatment process (see Figure 2)
Insert the sample exchange into the sample buffer and rotate to about 10 times the inner wall for the sample to dissolve as much in solution as possible.
1. Pour the liquid into the pipe along the front end of the inner wall of the pipe, take out and discard.
2. Cover with the hair dryer.

  
           Figure 2 Sample processing             

   

 

Figure 3 Detection procedure

 

(2) Test sequence (see Figure 3)
The 1. takes out the test card.
The 2. adds 2 drops of μ50) to put the test material into the test card and start the timer.
Read the results after 15 minutes at room temperature. After 5 minutes, the results are invalid

 

Interpretation of Test Results


Test card description (Figure 4)
① Invalid result: Quality Control Line (Line C) is invalid, no response line, and should be tested again.
② negative line result: The quality control line (line C) is a red ribbon.
③ The positive result is: two red bands, test line (T) and Quality Control Line (C) all colors.

Figure 4 Interpretation of test results

 

Limitation of test method


1. This product is used for qualitative testing and only for in vitro assisted diagnosis.
2.This product applies for nose samples. Other sample type results may be inaccurate or invalid.
3. appropriately adds samples for testing. Too large or too small sample size may lead to inaccurate results.
4.It should not be the sole basis for clinical trials and treatment. The final diagnosis can be made after a comprehensive evaluation of all clinical and experimental results.

 

Product Performance Indicators


1. detection limit: inactivated sars―cov-2 virus with the minimum detection limit of 6 × 102 TTID 50/ML
2. tests using company reference products and the results shall meet the requirements of company reference products.
2.1The  access rate of positively controlled products: the P 1-P 5 of the enterprise positively controlled products is certain.
2.2 Product times: N 1-N 10 of enterprise negative control products are negative.
2.3 Detection limit: minimum detection limit reference product L 1-L 3 is detected, L 1 is negative, L 2 and L 3 are positive.
2.4 Repeatability: Standard substances J 1 and J 2 are reused by the testing company 10 times.
(3) Cross-reaction: To assess potential interference with the 2019 NCO VAG test project, the following microbes and viruses were added to samples of a specified concentration, indicating that there was no cross-reaction and interference from various microbes and viruses.

 

 

SN Microorganisms Concentration Cross reaction
1 Coronavirus (HKU1, OC43, NL63 and 229E) 1.0×105TCID50/mL No
2 H1N1 influenza (new type A H1N1 influenza virus (2009), seasonal H1N1 influenza virus), H3N2, H5N1, H7N9 1.0×105TCID50/mL No
3 Influenza B (Yamagata strain, Victoria strain) 2.5×105TCID50/mL No
4 Respiratory syncytial virus 2.8×105TCID50/mL No
5 Group A, B, C of rhinovirus 2.0×105TCID50/mL No
6 Type 1, 2, 3, 4, 5, 7, 55 of adenovirus 2.0×105TCID50/mL No
7 Group A, B, C and D of enterovirus 2.0×105TCID50/mL No
8 EB virus 2.0×105TCID50/mL No
9 Measles virus 2.0×105TCID50/mL No
10 Human cytomegalovirus 2.0×105TCID50/mL No
11 Rotavirus 2.0×105TCID50/mL No
12 Norovirus 2.0×105TCID50/mL No
13 Mumps virus 2.0×105TCID50/mL No
14 Varicella-zoster virus 2.0×105TCID50/mL No
15 Mycoplasma pneumoniae 1.0×106CFU/mL No
16 Legionella pneumophila 1.0×106CFU/mL No
17 Haemophilus influenzae 1.0×106CFU/mL No
18 Streptococcus pyogenes (group A) 1.0×106CFU/mL No
19 Streptococcus pneumoniae 1.0×106CFU/mL No
20 Escherichia Coli 1.0×106CFU/mL No
21 Pseudomonas aeruginosa 1.0×106CFU/mL No
22 Neisseria meningitidis 1.0×106CFU/mL No
23 Candida albicans 1.0×106CFU/mL No
24 Staphylococcus aureus 1.0×106CFU/mL No

 

 

 

4. Interference substances: The 2019 NCO VAG trial was planned to add the following concentrations of drugs to the samples to assess their potential interference. The results showed that all drugs did not interfere with the test results of the reagent.

 

 

 

 

Interfering substances Concentration Interfering substances Concentration
Mucoprotein 1mg/mL Ribavirin 0.4mg/mL
Whole Blood 1% Fluticasone 0.5mg/mL
Oxymetazoline 10mg/mL Dexamethasone 5 mg/mL
Histamine hydrochloride 10mg/mL Triamcinolone acetonide 5mg /mL
Tobramycin 1mg/mL Levofloxacin 0.2 mg/mL
Oseltamivir 1mg/mL Azithromycin 0.1 mg/mL
Zanamivir 1mg/mL Ceftriaxone 0.4 mg/mL
Arbidol 0.5mg/mL Meropenem 0.2 mg/mL
 

                  

5. Hook effect: within the high concentration range of 1.0. No × 106 tcid 50/ml,no 19 ncov inactive culture was found.
6. Clinical studies used RT-PCR test reagent to evaluate 120 positive and 120 negative (RT-PCR test) and used Zhongxiu reagent. The results were as follows.

 

Nasal swab RT-PCR Sum
Positive Negative
Positive 116 2 118
Negative 4 118 122
Sum 120 120 240
Sensitivity 96.67%, (95%CI: 91.74%~98.70%)
Specificity 98.33%, (95%CI: 94.13%~99.54%)
 
 

Precautions


1. This product is used for in vitro diagnosis only.
2. This product is disposable and cannot be recycled.
3. Read the instructions carefully before 3. operation and strictly follow the reagent instructions.
4. Avoid severe environmental conditions including disinfectant 84, sodium hypochlorite, acid and alkali or acetaldehyde, other high concentrations of corrosive gases and dust, etc., the laboratory shall disinfect.
5. All samples and reagents used shall be considered as potentially infectious materials and shall be treated in accordance with local legislation.
6. Use reagents within the validity period indicated in the outer package. Use the test card as soon as possible after removal from the aluminum foil bag.

Logo interpretation


Do not re-use Store at 2℃~30℃
Consult instructions for use In vitro diagnostic medical devic
Batch code Use-by date
Keep dry Keep away from sunlight
Authorized representative in the European Community Manufacturer

 

 

Basic Information

 


 

ZHONGXIU SCIENCE AND TECHNOLOGY CO.,LTD

Dingluan industrial zone ,Changyuan City,453400,P.R.CHINA

Tel:+86-371-55016575

Email:zosbio@zosbio.com

SUNGO Europe B.V.

Olympisch Stadion 24, 1076DE Amsterdam, Netherlands

 

 

 

Company profile


 
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2016

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Lantian Medical Supplies Co.,Ltd.
  • Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.
  • https://www.agrapidtestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement