China New Coronavirus Neutralizing Antibody Rapid Test For Serum Plasma
China New Coronavirus Neutralizing Antibody Rapid Test For Serum Plasma

  1. China New Coronavirus Neutralizing Antibody Rapid Test For Serum Plasma
  2. China New Coronavirus Neutralizing Antibody Rapid Test For Serum Plasma

New Coronavirus Neutralizing Antibody Rapid Test For Serum Plasma

  1. MOQ: To be negotiated
  2. Price: To be negotiated
  3. Get Latest Price
Supply Ability 10000 Kit/Kit per Day
Delivery Time To be negotiated
Packaging Details Kit
Product name 2019-NCoV Neutralizing Antibody Rapid Test (Immunochromatography)
Composition Detection card, sample buffer
Storage conditions 2℃~30℃
term of validity twelve months
Sample requirements Serum, plasma or whole blood
Brand Name ZOSBIO
Model Number 2019-NCoV Neutralizing Antibody
Certification CE BfArm
Place of Origin Henan,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10000 Kit/Kit per Day Delivery Time To be negotiated
Packaging Details Kit Product name 2019-NCoV Neutralizing Antibody Rapid Test (Immunochromatography)
Composition Detection card, sample buffer Storage conditions 2℃~30℃
term of validity twelve months Sample requirements Serum, plasma or whole blood
Brand Name ZOSBIO Model Number 2019-NCoV Neutralizing Antibody
Certification CE BfArm Place of Origin Henan,China
High Light New Coronavirus Neutralizing Antibody Rapid TestSerum Coronavirus Neutralizing Antibody Rapid TestPlasma neutralizing antibody test for covid-19

2019-NCoV Neutralizing Antibody Rapid Test (Immunochromatography) Precautions

 

Intended Use


This kit is used to qualify the normal coronavirus (2019 ncov) neutralizing antibody in human serum, plasma and whole blood samples.
New coronavirus (2019 ncov) is a novel coronavirus β Coronavirus belongs to genus. It causes viral pneumonia, and is mainly caused by fever, sorrow, and cough, and there are not many patients with symptoms such as nasal congestion, DDT, sore throat, diarrhea. Severe respiratory distress syndrome, septic shock, metabolic acidosis, and coagulation disorder are progressed.
The novel coronavirus has several structural proteins, including stab (s), envelope (E), membrane (m), and nuclear capsid (n). The receptor binding domain (RBD) has tyrosine receptor 2 (acs2). In the present study, it was clarified that the tyrosine RBD of 2019 ncov strongly interacts with the ACE 2 receptor of the human body, and it causes the endocytosis of the host cell in the lung and replication of the virus.
2019 ncov infection and vaccination can result in an immune response, and antibodies can be made in the blood. The secreted antibody prevents viral infection and exists in the circulating system of the body for several months to several months after infection, and quickly binds with the pathogen to prevent the replication of the virus. These antibodies are called neutralizing antibodies. Detecting neutralizing antibodies can determine whether the ability to prevent viral infections is provided.

 

Principle of Detection


 

This kit uses immunochromatography. The inspection card contains a quality control line C, an inspection line T, and an inspection line R, and the sample to be examined (serum / plasma / whole blood) diffuses upward by the capillary action at the edge end. S-rbd, which contains markers in the binding pad, associates with the ACE2 protein immobilized in the NC membrane to detect the signal at the T line position. When neutralizing antibody is present in the sample, it is combined with the s-rbd antigen labeled in the marker pad. Neutralizing antibody inhibits s-rbd and ACE 2 binding, and signal values decrease. There was a negative correlation between the neutralizing antibody content and the signal value of the T line. The control line R and the quality control line C should be colored regardless of the color of the T line. Quality control line C is used for quality control, but if the C line has no color, the test is disabled, so the sample must be retested.
 

Main Components


The kit consists of a test card and a sample buffer.
Test card: aluminum foil bag, desiccant, tester sheet, plastic card. Of these, the sheet is composed of a water absorbing paper, a cellulose hydroxide film, a sample pad, a bonding pad, and an adhesive plate. There is an ACE 2 protein in the scaffold of the cellulose succinate membrane, the quality control line antibody is connected to the c-line (quality control line), and the contrast line is combined with the control line, and it is combined with the 2019 ncov antigen marked by the marker.
Sample buffer solution: phosphate, sodium azide

 

Storage Conditions and Validity


Save at 2 to 30 degrees Celsius, and the effective period is 12 months.
The aluminum foil bag is opened and the effective period is 1H.
Product lot number: see the label for details.
Product invalid date: see the label for details.

 

Sample Requirements


1 serum, plasma or whole blood samples.
Since precipitates and floatings in the sample may affect the experimental results, centrifugation must be removed.
Anticoagulants using anticoagulant heparin, EDTA and sodium citrate were not effective.
4. It is recommended that a professional medical staff should do so and prioritize serum / plasma examination. In case of an emergency or a special case, the patient's whole blood sample can also be used for quick inspection.
5.Serum and plasma samples can not exceed 8h at room temperature, can be stored at 5 to 8 degrees Celsius for 5 days, and can be kept at - 20 degrees Celsius for 6 months to avoid repeated freezing and thawing. The whole blood sample should not be frozen, and should not be stored above 48 h at 2 to 8 ° C.

Test Method


Please read the usage instructions before the test. Return all reagents to room temperature before the test. Test should be done at room temperature.
1. Take out the test card from the packed reagent bag and use it within 1 hour.
2.Sample (serum, plasma or whole blood) 20 μ 2 drops of sample buffer solution μ L).
3. Reading after 20 minutes is invalid.

 

Interpretation of Test Results


 

Explanation of the test card

1.An invalid result: the quality control line (C line) reaction line appears, the detection is invalid, and the retest should be done.
2.Negative result: the red band appears in the inspection line (t line), and the color is higher than the control line (r line), and the quality control line (C line) and the control line (r line) color.
3.Positive result: the red band does not appear in the inspection line (t line), and the red band appears in the inspection line (t line), but the color is lower than the control line (r line), and the quality control line (C line) and the control line (r line) color.

Limitation of Test Method


 

1.This kit is a qualitative test and is used only for in vitro diagnosis.
2. If the number of samples is too small or too small, the result may be inaccurate.
3. Hemolysis, lipidemia, jaundice, contamination samples should be avoided because it may affect the test results.
4. The results of this reagent are only provided for clinical reference and should not be the only basis for clinical practice, and the final diagnosis should be performed after overall evaluation of all clinical and laboratory results.

Product Performance Indicators


1. Specificity analysis

1.1Cross reaction: no interference was observed when the interference was tested for the following types of antibodies.

 

SN Item Cross reaction SN Item Cross reaction
1 Endemic human coronavirus OC43 No 10 Enterovirus No
2 Endemic human coronavirus HKUI No 11 EB virus No
3 Endemic human coronavirus NL63 No 12 Measles virus No
4 Endemic human coronavirus 229E No 13 Human cytomegalovirus No
5 Influenza A virus No 14 Rotavirus No
6 Influenza B virus No 15 Norovirus No
7 Respiratory syncytial virus No 16 Mumps virus No
8 Adenovirus No 17 Varicella-zoster virus No
9 Rhinovirus No 18 Mycoplasma pneumoniae No

 

1.2 In order to evaluate the possibility of interferers, the following concentrations were added to the specified concentration samples. As a result, it was shown that various interferences did not interfere with the detection result of this reagent.

 

Interfering substances Concentration Interfering substances Concentration
Bilirubin ≤50mg/dL Triglycerides ≤15mmol/mL
Hemoglobin ≤5g/L Cholesterol L ≤500mg/d
Rheumatoid factor ≤500IU/mL Human total IgG ≤14mg/mL
Ribavirin 0.4mg/mL Fluticasone 0.5mg/mL
Oxymetazoline 10mg/mL Dexamethasone 5 mg/mL
Histamine hydrochloride 10mg/mL Triamcinolone acetonide 5mg /mL
Tobramycin 1mg/mL Levofloxacin 0.2 mg/mL
Oseltamivir 1mg/mL Azithromycin 0.1 mg/mL
Zanamivir 1mg/mL Ceftriaxone 0.4 mg/mL
Arbidol 0.5mg/mL Meropenem 0.2 mg/mL

 

2.Clinical study: a novel test of the normal coronavirus (2019-ncov) IgG antibody test reagent (colloidal gold method) was carried out as a comparative reagent, and 120 positive and 300 samples were tested

 

 

2019-nCoV IgG Ab detection reagent (colloidal goldmethod)

 

Sum

Positive Negative

Positive 115 5 120
Negtive 5 295 300
Sum 120 300 420
Sensitivity 95.83%, (95%CI: 90.62%~98.21%)
Specificity 98.33%, (95%CI: 96.16%~99.29%)

 

 

Precautions


1.This product is for in vitro diagnosis.
2. This product is disposable, and cannot be used again.
3.
Avoid disseminated environments such as 84 disinfectants, sodium hypochlorite, acid alkaloids, acetaldehyde, and so on.
5. All samples and Empress's reagents are regarded as potential infectious substances and must be treated according to the local laws when disposing.
6.The reagent should be used within the effective period of the display of packaging. Use the soap card from the aluminum foil bag as soon as possible and prevent moisture.

Company profile


 
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2016

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Lantian Medical Supplies Co.,Ltd.
  • Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.
  • https://www.agrapidtestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement