China factories

China factory - Henan Lantian Medical Supplies Co.,Ltd.

Henan Lantian Medical Supplies Co.,Ltd.

  • China,Zhengzhou ,Henan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Radiation Sterilization Heel Blood Collector 3 Years Validity Period
China Radiation Sterilization Heel Blood Collector 3 Years Validity Period

  1. China Radiation Sterilization Heel Blood Collector 3 Years Validity Period
  2. China Radiation Sterilization Heel Blood Collector 3 Years Validity Period

Radiation Sterilization Heel Blood Collector 3 Years Validity Period

  1. MOQ: To be negotiated
  2. Price: To be negotiated
  3. Get Latest Price
Delivery Time To be negotiated
Product Name Heel Blood Sampler Matters Needing Attention
Model and specification Model and specification
Packing 50 pieces per box
production date see packing box
Scope of application It is mainly used for heel blood collection of newborns
Brand Name ZOSBIO
Model Number Heel Incision Device
Place of Origin Henan,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Delivery Time To be negotiated Product Name Heel Blood Sampler Matters Needing Attention
Model and specification Model and specification Packing 50 pieces per box
production date see packing box Scope of application It is mainly used for heel blood collection of newborns
Brand Name ZOSBIO Model Number Heel Incision Device
Place of Origin Henan,China
High Light Radiation Sterilization Heel Blood SamplerHeel Blood Collector 3 Years ValidityRadiation Sterilization heel blood collector

Product structure And Composition


The heel blood collector is composed of a shell, a spring, a blade and an elastic part. The housing and elastic parts are made of ABS (Acrylonitrile-Butyrene-Benzodiene) material. The spring is made of carbon spring wire. The blades are made of stainless steel.


Product Performance


  • The appearance of the heel sampling device should be kept clean and free of obvious burrs, stains, imperfections and other injector imperfections. Blade without scraper, hook and other defects.
  • The heel sample was well assembled and the casing was consistent without obvious dislocation.
  • The surface hardness of the blade is above 350HV10. The Ra value of leaf roughness is less than 0.4μm.
  • The corrosion resistance of mountain blood sampling blade should reach grade B (corrosion traces can be wiped out).
  • The blade of the heel blood collector can be inserted after use and the blade is in the skin.
  • The sterilization method is radiation sterilization, the product must be aseptic.
  • The blade of heel blood collector should have no heat source reaction.

 

Specifications And Dimensions


Specifications and dimensions of hill blood sampler
Specification (mm) Incision depth (mm) Incision length (mm)
0.85mm/1.75mm 0.85mm±0.05 1.75mm±0.05
1.00mm/2.50mm 1.00mm±0.05 2.50mm±0.05

 

 

Usage Method


1. The baby lies down and the part needed for blood collection is wiped with a cotton swab for disinfection and then dried naturally. Do not touch the disinfected area.
2. Do not remove the outer package of the blood collector, and place the blood collector in an unsterilized place. Remove the safety clasp of the blood collector and do not press the launch button or touch the blade.
3. Lift the baby's feet higher than the heart, and select a safe location for blood collection according to the "Baby Blood Collection Site Map", so that the blood collection mouth is vertically aligned with the blood collection site.
4. When the flat end of the blood collection mouth touches the skin, press the launch button to collect blood, and the blood collection device moves quickly to the site of the blood collection.
5. Gently wipe the first drop of blood with a dry germicidal gauze.
6.1 Press carefully and moderately, and collect appropriate blood samples with a blood sample tube. After blood collection, dry heat sterilized gauze was used to gently press the incision to stop bleeding and prevent hematoma.
6.2 Drop blood directly into the transfusion jacquard card to sample as appropriate, and then collect at least 3 consecutive blood marks. After blood collection, gently press the wound with a dry heat sterilizing cloth to stop bleeding and prevent hematoma.

Contraindication


1. Use with infants (including heat) unless necessary.
2. Please do not take blood in the same place twice.
3. Do not use it for infants with edema, infection or inflammation at the puncture site.
4. Do not use the puncture site because of children's skin diseases or skin injuries.
5. Do not select skin within 2mm of the previous sampling site.

 

Matters Needing Attention


1. Do not use the blood collection device if the safety buckle is lost or the mouth is damaged.
2. The blood sample is disposable. Please renew each blood sample.
3. The safe area for baby blood sampling is between the green line between the 4th and 5th toes parallel to the feet and the green line from the thumb parallel to the feet.
4. The disinfection diameter of the blood collection part must be no less than 2cm.
5. Underdeveloped blood vessels lead to insufficient blood flow.
6. If the heel needs to be preheated, 42 to 44℃ will help to promote blood flow, but above 44℃ will lead to burns.
7. The blood collection part shall be attached to the blood collection part and inserted into the needle vertically, but shall not exert too much force to avoid causing deep and deep injury.
8. Please pay attention when using the blood collection device to prevent accidental injury to yourself and others.
9. In order to prevent bleeding or inflammation after blood collection, attention should be paid to the site of blood collection.
10. The blood collection device is irradiated and sterilized with a period of validity of 3 years. When the expiry date is exceeded, it is strictly prohibited to use.
11. The blood collection device may be infected after use. In order to prevent contamination and injury, it should not be discarded at will.

 

Keep In Storage


It should be stored in a cool, dry, ventilated and clean environment with corrosive gas, relative humidity below 80% and temperature below 45℃.

 

 

Company profile


ZOS-F2100(Multi-Channel) 4ZOS-F2100(Multi-Channel) 5ZOS-F2100(Multi-Channel) 6ZOS-F2100(Multi-Channel) 7

Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2016

  • Employee Number:

    500~1000

  • Ecer Certification:

    Active Member

Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi... Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is located in Dingluan Industrial Zone, Changyuan City, Henan Province. The company covers an area of about 100 acres and the initial investment is about 200 million yuan. The company has a scientific and complete management system, a purifi...

+ Read More

Get in touch with us

  • Reach Us
  • Henan Lantian Medical Supplies Co.,Ltd.
  • Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.
  • https://www.agrapidtestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement