China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean
China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean

  1. China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean
  2. China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean
  3. China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean
  4. China Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean

Innovating Aerosol Based Automatic Fire Suppression System Eco Friendly Clean

  1. MOQ: 1
  2. Price: Negotation
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union, MoneyGram
Supply Ability 20000~50000 sets per month
Delivery Time 1-6weeks( depends on QTY,samples in stock)
Packaging Details Carton Packing
Item Fixed Type Innovating Aerosol Extinguishing Systems Eco-friendly Clean Agent
Extinguishing device weight(Kg) 6.8
Agent quantity(Kg) 3.5
Protected volume (m³) 125m³
MSDS we have for export
Discharge time(s) ≤19
Typical applications underground pipeline/ control room/ equipment room/Storage Room
Model Fireless 125
Brand Name Fireless
Model Number Fireless 125
Certification BSI/ILAC-MRA/CNAS/AL/MA
Place of Origin Jiangsu

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union, MoneyGram Supply Ability 20000~50000 sets per month
Delivery Time 1-6weeks( depends on QTY,samples in stock) Packaging Details Carton Packing
Item Fixed Type Innovating Aerosol Extinguishing Systems Eco-friendly Clean Agent Extinguishing device weight(Kg) 6.8
Agent quantity(Kg) 3.5 Protected volume (m³) 125m³
MSDS we have for export Discharge time(s) ≤19
Typical applications underground pipeline/ control room/ equipment room/Storage Room Model Fireless 125
Brand Name Fireless Model Number Fireless 125
Certification BSI/ILAC-MRA/CNAS/AL/MA Place of Origin Jiangsu
High Light aerosol fire systemaerosol fire protection

Fixed Type Innovating Aerosol Extinguishing Systems Eco-friendly Clean Agent

 

Brief requirements of Aerosol Extinguishing Systems according to GA499.1-2010

  • Spray process and state-fire extinguishing device should be able to spray normally after switching on the start signal
  • During discharge, there shall be no open fire or spark at the nozzle, and no residue shall overflow during or after injection
  • After the completion of spraying, the shell shall not be deformed, burnt through or ignited on the surface of the shell.
  • The total filling mass of aerosol generator in a fire extinguishing device shall not be more than 10kg, and the deviation of filling mass shall not exceed 2% of its nominal mass.
  • The operating voltage of the electric initiator shall not be greater than 24 vd.c.
  • The raw materials used to produce aerosol generating agents should be non-toxic to organisms and the combustion products do not contain harmful ingredients that damage the atmospheric ozone layer.

 

Fireless 125 technical parameter:

Item Specification
Overall dimensions(mm) 240( diameter)X126(height)
Extinguishing device weight(Kg) 6.8
Agent quantity(Kg) 3.5
Protected volume(m³) 125
Working temperature(℃) -50℃~+95℃
Safety current(mA,DC) ≤150mA
Discharge times) ≤ 19
Service life(year) 10

 

FAQ for technical terms

  • Do the protected area needed 100% closed?

Answer: no, it doesn’t .

  • what is ratio of open area to total area in enclosure?

Answer:Represents the unsealing degree of the enclosed space, and its value is the ratio of the unclosed open area in the enclosed space to the total surface area, expressed as a percentage.

  • What is flame extinguishing density?

Answer:The mass of an aerosol agent required to extinguish a fire in unit volume, g/m³.

  • What is discharge delay time?

Answer:The time when the fire extinguishing device receives the starting signal and the nozzle begins to spew hot gas sol extinguishing agent.

  • What is discharging time?

Answer:The time from the beginning discharging aerosol to discharging stopped.

  • What is outlet temperature in discharging?

Answer:During the process of discharge heat aerosol fire extinguishing agent, the outlet temperature is where 5 meters away from nozzle.

  • Is there any cooling equipment in the generator?

Answer:Yes, it’s medium or device installed in a fire extinguishing device to effectively reduce the temperature of a hot gas aerosol extinguishing agent before it passes through the nozzle.

 

Application:

data centers/ UPS/ ESP/ museums/ warehouses/ electric cabinets/ generator rooms panels/ engine rooms/ different transportation vehicles

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2003

  • Total Annual:

    15000-30000

  • Employee Number:

    100~1500

  • Ecer Certification:

    Active Member

  ABOUT US NOVTEC means “Technology &Innovation”. It is the company behind FireLess. Fireless is developped from Chinese Military Smoke technology and now it is a transformation from military product to civil field. As one of the latest generation of high efficient ...   ABOUT US NOVTEC means “Technology &Innovation”. It is the company behind FireLess. Fireless is developped from Chinese Military Smoke technology and now it is a transformation from military product to civil field. As one of the latest generation of high efficient ...

+ Read More

Get in touch with us

  • Reach Us
  • Novtec Technology Co .,Ltd
  • Building C21, No.2588,WuzhongRoad,Wuzhong economic development zone,Suzhou City
  • http://www.aerosolsuppressionsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement