Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 20000~50000 sets per month |
Delivery Time | 1-6weeks( depends on QTY,samples in stock) |
Packaging Details | Carton Packing |
Item | Advanced Aerosol Fire Suppression System for Electrical Substation |
Application | Electrical Substation |
Agent quantity(Kg) | 1.4 |
Protected volume (m³) | 50 m³ with one unit |
Ingredient | Potassium salts with non-pyrotechnic materials |
Advantage | No required expensive pipes work |
Brand Name | Fireless |
Model Number | Fireless 50 |
Certification | BSI |
Place of Origin | Jiangsu |
View Detail Information
Explore similar products
Throwable Aerosol Systems Fire Suppression / Manual KnockdownAerosol Fire
Wind TurbineAerosol Fire Suppression Protecting Nacelle Electrical Cabinets
Clean Agent Aerosol Fire Suppression Apply In Cabinet Fire Class A - E
Condensed Aerosol Fire Suppression System Innovative Revolutionary 0.16kg
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Supply Ability | 20000~50000 sets per month |
Delivery Time | 1-6weeks( depends on QTY,samples in stock) | Packaging Details | Carton Packing |
Item | Advanced Aerosol Fire Suppression System for Electrical Substation | Application | Electrical Substation |
Agent quantity(Kg) | 1.4 | Protected volume (m³) | 50 m³ with one unit |
Ingredient | Potassium salts with non-pyrotechnic materials | Advantage | No required expensive pipes work |
Brand Name | Fireless | Model Number | Fireless 50 |
Certification | BSI | Place of Origin | Jiangsu |
High Light | aerosol fire extinguishing generators ,aerosol generator fire suppression |
Advanced Aerosol Fire Suppression System for Electrical Substation
The importance of substations
As an important node from the transmission network system to the end users, the substation is a layered hub of a city power supply system, supporting the needs of residents and industrial electricity. Therefore, the safety risk prevention and control of the substation is an important link to ensure the safe operation of the power network. Therefore, the safety risk prevention and control of the substation is an important link to ensure the safe operation of the power network.
Due to the many sub-substations with many nodes, complicated operation equipment, high-voltage equipment and 24 hours of uninterrupted operation, there is a large fire risk in actual operation, the direct and indirect serious damage and loss will be caused in the event of a fire accident. For the sudden affairs, whether the fire protection system can be put into operation normally, it is often important to suppress and extinguish the early fires. With the growth of technology and the improvement of automation level, there will be more and more unattended substations.
The advantages of FireLess 50
1. FireLess 50 has small volume and modular design that make it can adapt the smaller or bigger size electrical cabinets or distribution cabinets.
2. Electric start and automatic mechanical temperature sensing start make it can detect the early fires accurately, to control and extinguish the fires in time, decrease the downtime and further damages to the equipment, and reduce the losses. In particular for those remote and unattended substations, FireLess provide a perfect solution for them.
3. FireLess suppression systems are not pressurized and does not destroy the equipment and facilities in second time.
4. Very easy to install and use
5. No required expensive pipes work
6. Minimal maintenance cost
Technical parameters for Aerosol Fire Extinguishing System
Item | Specification |
Overall dimensions(mm) | 240( diameter)X69(height) |
Extinguishing device weight(Kg) | 3.4 |
Agent quantity(Kg) | 1.4 |
Protected volume(m³) | 50 |
Working temperature(℃) | -50℃~+95℃ |
Safety current(mA,DC) | ≤150mA |
Electric start-up time(s) | ≤0.1 |
Discharge times) | ≤ 9 |
Service life(year) | 10 |
Cost | No required expensive pipes work |
Performance | Highly effective based on required density |
The characteristics of substations
The substation operating environment is more complicated and usually located in remote and distant locations, and there are many lurking unsafe factors which are electrical fires.
(1) The equipment has high value and huge direct losses and indirect losses.
(2) The concentration of combustible materials is high and the fire load density is high. Fires are mostly hidden fires and are not easy to find.
(3) Materials and cables are ignited, which are prone to generate a large amount of smoke and toxic gases and electrical equipment leakage. Fire extinguishing may cause secondary accidents such as poisoning and electric shock, which may cause casualties.
(4) The flame spreads quickly and the equipment threatens each other.
(5) Fire rescue takes a long time
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2003
Total Annual:
15000-30000
Employee Number:
100~1500
Ecer Certification:
Active Member
ABOUT US NOVTEC means “Technology &Innovation”. It is the company behind FireLess. Fireless is developped from Chinese Military Smoke technology and now it is a transformation from military product to civil field. As one of the latest generation of high efficient ... ABOUT US NOVTEC means “Technology &Innovation”. It is the company behind FireLess. Fireless is developped from Chinese Military Smoke technology and now it is a transformation from military product to civil field. As one of the latest generation of high efficient ...
Get in touch with us
Leave a Message, we will call you back quickly!