Payment Terms | T/T |
Supply Ability | 5000pc/day |
Delivery Time | 5-8 work days |
Packaging Details | carton |
Input current | 2000A |
Output current | 1/5A |
Type | Split Core Current Transformer |
Brand Name | Acrel |
Model Number | AKH-0.66/K K-120*60 2000 |
Certification | UL |
Place of Origin | China |
View Detail Information
Explore similar products
IEC/EN61869-2 Standard Rectangular Split Current Transformer 50Hz AKH-0.66/K
Acrel AKH-0.66-40I Series Split Core Current Transformer Ac Current Transmitter
Acrel AKH-0.66 P26 Medical Protective Current Transformer CT For Medical
AKH-0.66-K-24 150/5A Split Core Current Transducer 720V AC
Product Specification
Payment Terms | T/T | Supply Ability | 5000pc/day |
Delivery Time | 5-8 work days | Packaging Details | carton |
Input current | 2000A | Output current | 1/5A |
Type | Split Core Current Transformer | Brand Name | Acrel |
Model Number | AKH-0.66/K K-120*60 2000 | Certification | UL |
Place of Origin | China | ||
High Light | AKH-0.66/K split core square current transformer ,2000/5(1)A split core square current transformer |
AKH-0.66/K Series Split Core Current Transformer
AKH -0.66K series open-type current transformers are mainly used in industrial urban and rural power grid reconstruction projects.
They are easy to install and do not need to disassemble the primary busbar. They can also be used for live measurement and metering devices. operation, without affecting the normal electricity consumption of customers, saving manpower, material and financial resources for user transformation projects, and improving efficiency. This series of current transformers can be used in conjunction with relay protection measurement and metering devices.
Size and dimensions
Size(mm) Specification | Outline size | Through size | Mountng size | Tolerance | |||||
W | H | D | a | e | P | Q | |||
K-30×20 | 90 | 114 | 40 | 22 | 32 | 50 | 32 | ±1 | |
K-60×40 | 114 | 140 | 36 | 42 | 62 | 45 | 33 | ||
K-80×40 | 122 | 162 | 40 | 42 | 82 | 45 | 33 | ||
K-80×50 | 114 | 159 | 36 | 52 | 82 | 45 | 32 | ||
K-80×80 | 144 | 159 | 36 | 82 | 82 | 45 | 33 | ||
K-120×80 | 144 | 194 | 52 | 42 | 102 | 56 | 36 | ||
K-120×60 | 164 | 214 | 52 | 62 | 122 | 56 | 36 | ||
K-100×40 | 144 | 199 | 36 | 82 | 122 | 45 | 32 | ||
K-130×40 | 144 | 224 | 52 | 42 | 132 | 56 | 36 | ||
K-130×50 | 145 | 222 | 50.5 | 54 | 130 | 56 | 36 | ||
K-130×60 | 170 | 222 | 70 | 60 | 130 | 56 | 36 | ||
K-140×60 | 164 | 234 | 52 | 62 | 142 | 56 | 36 | ||
K-160×80 | 184 | 254 | 52 | 82 | 162 | 56 | 36 | ||
K-200×80 | 184 | 294 | 52 | 82 | 202 | 56 | 36 |
4.Cross-reference tables of spec.-parameter | ||||||||||
![]() ![]() | Type | Rated current ratio(A) | Precision degrec | Rated load,VA | ||||||
K-30×20 | 20-75/1A | 0.2 | ||||||||
100-150/5(1)A | 1 | |||||||||
200/5(1)A | 1 | 1.5 | ||||||||
250-300/5(1)A | 0.5 | 1.5 | ||||||||
350-400/5(1)A | 0.5 | 2.5 | ||||||||
K-60×40 | 250-300/5(1)A | 1 | 1.5 | |||||||
350-450/5(1)A | 0.5 | 1.5 | ||||||||
500-800/5(1)A | 0.5 | 2.5 | ||||||||
1000-1250/5(1)A | 0.5 | 5 | ||||||||
1500-2000/5(1)A | 0.5 | 10 | ||||||||
K-80×40 | 350-450/5(1)A | 0.5 | 2.5 |
| 500-800/5(1)A | 0.5 | 5.0 | |
1000-2000/5(1)A | 0.5 | 10 | ||
2500/5(1)A | 0.2 | 10 | ||
K-80×50 | 250-300/5(1)A | 1 | 1.5 | |
400-450/5(1)A | 0.5 | 1.5 | ||
500-800/5(1)A | 0.5 | 2.5 | ||
1000/5(1)A | 0.5 | 5 | ||
K-80×80 | 250-300/5(1)A | 1.5 | ||
400-450/5(1)A | 0.5 | 1.5 | ||
500-800/5(1)A | 0.5 | 2.5 | ||
1000/5(1)A | 0.5 | 5 | ||
K-100×40 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-3000/5(1)A | 0.2 | 10 | ||
4000A/5(1)A | 0.2 | 15 | ||
K-120×60 | 400-450/5(1)A | 0.5 | 2.5 | |
500-800/5(1)A | 0.5 | 5.0 | ||
1000-2000/5(1)A | 0.5 | 10 | ||
2500-4000/5(1)A | 0.2 | 10 | ||
K-120×80 | 500-800/5(1)A | 0.5 | 2.5 | |
1000-1200/5(1)A | 0.5 | 5 | ||
1250-1500/5(1)A | 0.5 | 7.5 | ||
K-130×40 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-4000/5(1)A | 0.2 | 10 | ||
K-130×50 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-3000/5(1)A | 0.2 | 10 | ||
4000-5000/5(1)A | 0.2 | 15 | ||
K-130×60 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-5000/5(1)A | 0.2 | 15 | ||
K-140×60 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-3000/5(1)A | 0.2 | 10 | ||
4000-5000/5(1)A | 0.2 | 15 | ||
K-160×80 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-3000/5(1)A | 0.2 | 10 | ||
4000-5000/5(1)A | 0.2 | 15 | ||
K-200×80 | 1000-2000/5(1)A | 0.5 | 10 | |
2500-3000/5(1)A | 0.2 | 10 | ||
4000-5000/5(1)A | 0.2 | 15 |
Company
Contact us
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
0.5million-1.5million
Employee Number:
1000~1500
Ecer Certification:
Verified Supplier
Jiangsu Acrel Electrical Manufacturing Co., LTD, located in Jiangyin City,Jiangsu Province,which is a wholly-owned subsidiary of Acrel Co., Ltd.[stockcode :300286.SZ]. It is a high-tech enterprise in Jiangsu Province and a pioneer enterprise integrates the informatization and industrialization of Ji... Jiangsu Acrel Electrical Manufacturing Co., LTD, located in Jiangyin City,Jiangsu Province,which is a wholly-owned subsidiary of Acrel Co., Ltd.[stockcode :300286.SZ]. It is a high-tech enterprise in Jiangsu Province and a pioneer enterprise integrates the informatization and industrialization of Ji...