Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
ConsentDo not consent
Wenzhou Modern Group Co., Ltd. ( Wenzhou Modern Completed Electric-power Equipment Co., Ltd. )
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Advanced Static Var Harmonic Filter Generators High Power Density","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/e3\/a1\/2321f2a5f15d1d69f71952582ecb-200x200-1\/advanced_static_var_harmonic_filter_generators_high_power_density.jpg","attrs":{"Brand Name":"OEM\/ODM","Model Number":"ASVG","Place of Origin":"China","Minimum Order Quantity":"1"}}
{"title":"Static Var Generators Harmonic Filter Dustproof Module Are Compact","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/3f\/e0\/60c3584cd7dddad375c70e97a007-200x200-1\/static_var_generators_harmonic_filter_dustproof_module_are_compact.jpg","attrs":{"Brand Name":"OEM\/ODM","Model Number":"SVG","Place of Origin":"China","Minimum Order Quantity":"1"}}
{"title":"Active Power Filter APF Excellent Sealing Interleaving Control","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/d3\/29\/af3c9955e5093cf44e5647047e93-200x200-1\/active_power_filter_apf_excellent_sealing_interleaving_control.jpg","attrs":{"Brand Name":"OEM\/ODM","Model Number":"APF","Place of Origin":"China","Minimum Order Quantity":"1"}}
{"title":"3 Phase 150A Power Factor Correction Device System for Pakistan Active Power","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/8e\/6b\/2678bc00cb461afcd5f35be333d2-200x200-1\/3_phase_150a_power_factor_correction_device_system_for_pakistan_active_power_filter.jpg","attrs":{"Brand Name":"Modern","Model Number":"LBJ-F","Certification":"ISO 9001","Place of Origin":"China"}}
{"title":"High Frequency 200KVA Three Phase Active Harmonic Filter Beige Copper 380V \/","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/36\/16\/63545f04cf739f5f58f5a4411ef0-200x200-1\/high_frequency_200kva_three_phase_active_harmonic_filter_beige_copper_380v_2f_400v.jpg","attrs":{"Place of Origin":"China","Brand Name":"Modern","Certification":"ISO 9001","Model Number":"LBJ-T"}}
{"title":"high speed Three Phase 300 KVAR Active Harmonic Filter Active Power Filter","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/03\/02\/8f4fd11f1517657096bee0f029f9-200x200-1\/high_speed_three_phase_300_kvar_active_harmonic_filter_active_power_filter.jpg","attrs":{"Place of Origin":"China","Brand Name":"Modern","Certification":"ISO 9001","Model Number":"LBJ-T"}}
{"title":"High \/ Low voltage Single Phase Active Harmonic Filter APF 220V \/ 230V 100 KVAR","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/8b\/ff\/6be4706fb1c3111c336da3bb0e95-200x200-1\/high_2f_low_voltage_single_phase_active_harmonic_filter_apf_220v_2f_230v_100_kvar.jpg","attrs":{"Place of Origin":"China","Brand Name":"Modern","Certification":"ISO 9001","Model Number":"LBJ-T"}}
Introduction to Modular Power Quality Regulators Our modular power quality products include: Static Var Generators (SVGs), Advanced SVGs (ASVGs) and Active Power Filters (APFs). They have features such as high power density, enhanced reliability, optimized performance, high utilization and unique designs. For use in different application scenarios, there are three way to install them: drawer style, wall-mounted style and upright style.
Main Features of Modular Power Quality Regulators Our modular power quality regulators:
Are compact, with a maximum size of only 0.05m³, have a high power density, and apply to a variety of scenarios. In practice, they are more applicable to places where limited space poses a stringent requirement on the ground they could cover, as well as power distribution upgrading projects.
Employ the same design concepts as industry-grade products, and therefore, highly adaptable to the environment.
Furnish the module control layer with a board compartment that reaches a dust-proof rating of IP6X and has withstood the nationally recognized third-party lab testing.
Apply an interleaving control manner at the output end. This reduces at least 40% of global ripple current.
Support a dynamic response at ms level, with a global response time less than 2ms. Therefore, they can accurately track how transient current changes in the power grid and prevent over-compensation and under-compensation.
Employ an industry-leading redundant design based on Insulated Gate Bipolar Transistors (IGBTs). As a result, failure in one line will not affect the proper running of the system.
Allow devices to detach from the power grid in case of a breakdown, with no port capacitors remain connected to the grid, thus preventing any negative impact on the harmonic oscillator and capacitive reactive power of the grid.
Support a CT connecting at the power supply side or the load side, which you can adjust according to on-site requirements.
Have a fast and thorough fault self-diagnosis function, which can be intelligently adjusted based on actual operating conditions and states.
Make it easier to maintain by using separately removable parts such as bus capacitor and fan.
Support a smart algorithm, which automatically adjusts the compensation proportion based on real-time changes in reactive current and harmonic current, and also supports flexibly setting a compensation goal, in order to optimize your business objective.
Support smart sleep in which two parallel systems apply a polling mechanism to allocate an average worktime for each module under a light load condition, thus extending module lifetime.
Have passed the CE certification and conform to EN 62477-1: 2012+A11-2014+A1-2017 standard;
Each of our products has the following compensation feature:
An APF supports a wider range of compensation, that is, instantaneous 2nd - 51st harmonic compensation;
An ASVG supports 2nd - 23rd harmonic compensation. You can set harmonic compensation capacity and reactive compensation capacity globally.
An SVG supports global, instantaneous compensation for inductive reactive power and capacitive reactive power, and meanwhile, solves the three phase unbalance problem.
Enhanced Reliability & Performance Industry-first dust-proof module at the control layer: The control section is separated from the power section. The control layer applies a fully closed dust-proof design, with no vent holes at two sides, front and back, thus obtaining an excellent sealing; while at the air cooling layer, critical power units are cooled by the power layer, thus achieving a superior device cooling performance. In addition, the control layer reaches a protection class of IP6X and has withstood the third-party lab testing. This isolates the control section from being polluted by the outer world. Besides, we employ an industry-grade hardware design, which further improves security and reliability.
At the dust-proof certification test After the dust-proof certification test
Use of a separate control scheme for each IGBT, which is much more reliable because: each IGBT is equipped with a set of drives and a hall element, and in the case that the IGBT on one side fails, the device still could offer 50% of the rated output capacity.
Providing a soft-start relay and resistor between a filter capacitor and the power grid, to ensure that when a device fails, the filter capacitor breaks away from the grid, without posing any secondary impact on the grid.
Quicker response: Use of a Second-Order Generalized Integration (SOGI) algorithm achieves a global response time of less than 2ms, making it possible to accurately tract how harmonic content and reactive content change in the power grid and prevent over-compensation and under-compensation.
In the response test of a sudden load rise, the oscillometer record shows that the global response time on the display is 1.36ms. In the response test of a sudden load drop, the oscillometer record shows that the global response time on the display is 1.96ms.
Advanced harmonic suppression technology: Quickly suppresses the harmonic state in less than 1s after a device detects that harmonic current is inevitable in the power grid, making sure that the device will not be turned off entirely so that it can go on performing compensation for the system.
Low ripple output: An interleaving-based low-ripple control technology achieves a smooth waveform even for a 60th harmonic output.
Modular APF/ASVG/SVG Model
ASVG/SVG Model for Quick Selection
Transformer Capacity (kVA)
CosФ
<0.5
0.5 - 0.6
0.6 - 0.7
0.7 - 0.8
0.8 - 0.9
1000
550kvar
550kvar
450kvar
350kvar
200kvar
1250
600kvar
600kvar
550kvar
450kvar
235kvar
1600
800kvar
800kvar
700kvar
550kvar
300kvar
Remarks
1. For use in harsh environment, we recommend industry-specific cabinet-style products; 2. For use in scenarios where harmonic current and reactive current are excessively large, configure our products based on actual calculation or in-site test data.
Modular ASVG Parameters
Model
ASVG15kvar
ASVG25kvar
ASVG35kvar
ASVG50kvar
ASVG70kvar
ASVG100kvar
System Parameters
Grid voltage
400V (-40% - +20%)
Grid frequency
50Hz/60Hz (±10%)
Pieces to be integrated
No limit
Efficiency
Up to 98%
Wiring mode
3-phase 3-wire/3-phase 4-wire
Heat loss
<2%
CT
150/5 - 10000/5
Connection mode
Connect from the back/top
Air in/out
Front to back/Top to bottom
Performance Indicators
Global response time
<2ms
Harmonic compensation order
2 - 23
Power factor
Adjustable from -1 - +1
Cooling mode
Intelligent air cooling
Noise
<58dB
Fixing mode
Drawer style, wall-mounted style and upright style
*Allocating rated power for compensation: You can select a proportion of the global rated power based on your settings to compensate for harmonic current and reactive current. 100% indicates that all of the global rated power is used for harmonics compensation.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Year Established:
1979
Total Annual:
7 million-8 million
Employee Number:
200~300
Ecer Certification:
Site Member
Better Power Quality, More Energy Saving
Wenzhou Modern Group(MODERN) is one of a leading company in designing and manufacturing Power Quality and Energy Saving products in the world.
Wide Power Solutions
Since 1979, MODERN has pioneered improvements in power solutions sectors for...
Better Power Quality, More Energy Saving
Wenzhou Modern Group(MODERN) is one of a leading company in designing and manufacturing Power Quality and Energy Saving products in the world.
Wide Power Solutions
Since 1979, MODERN has pioneered improvements in power solutions sectors for...