Payment Terms | L/C, T/T, Western Union |
Supply Ability | 60,000 per month |
Delivery Time | 25-30days |
Packaging Details | Cartons with pallet |
Sealed Type | Sealed |
Voltage | 12V |
Capacity | 150AH |
Plates | Lead Calcium |
Battery Size | 551/110/287mm |
Terminal | F14 |
Battery type | GEL |
Maintenance Type | Free |
Usage | UPS |
Customization | Customized logo and packaging |
Brand Name | FOBERRIA |
Model Number | FT12-150 |
Certification | CE IEC |
Place of Origin | China |
View Detail Information
Explore similar products
Solar 12V maintenance free battery Front Terminal Battery 150ah Deep Cycle Lead
Solar System 12V 180ah VRLA Lead Acid Battery FT Series
Deep Cycle UPS AGM Front Terminal 12v 150ah Battery For Solar Power System
Lead Calcium 12V 180Ah Front Terminal Battery For Backup Power
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 60,000 per month |
Delivery Time | 25-30days | Packaging Details | Cartons with pallet |
Sealed Type | Sealed | Voltage | 12V |
Capacity | 150AH | Plates | Lead Calcium |
Battery Size | 551/110/287mm | Terminal | F14 |
Battery type | GEL | Maintenance Type | Free |
Usage | UPS | Customization | Customized logo and packaging |
Brand Name | FOBERRIA | Model Number | FT12-150 |
Certification | CE IEC | Place of Origin | China |
High Light | 12v 150ah Agm Deep Cycle Battery ,Sealed 12v 150ah Deep Cycle Battery ,Front Terminal Agm 12v 150ah |
AGM manufacture price Front Terminal 12v 150ah Deep Cycle Battery
>Precautions
• Always handle batteries with care.
• Always store upright.
• Never over-fill with acid.
• Always charge in a well ventilated place.
• Always wear eye protection when handling batteries.
• Wear protective clothing if there is any rick of acid splashing.
Cells Per Unit | 6 | ||
Voltage Per Unit | 12 | ||
Capacity | 100Ah @10hr-rate to 1.80V per cell @ 25℃ | 150Ah @10hr-rate to 1.80V per cell @ 25℃ | 200Ah @10hr-rate to 1.80V per cell @ 25℃ |
Weight | 31.0KG | 43.5KG | 61.0KG |
Max. Discharge Current | 1000A(5 sec) | 1500A(5 sec) | 1000A(5 sec) |
Internal Resistance | Approx. 5.5mΩ | Approx. 5.0 mΩ | Approx. 4.5 mΩ |
Recommended Maximum Charging Current Limit |
30A |
45A | 60A |
Operating Temperature Range | Discharge: -20℃~60℃ Charge:0℃~50℃ Storage:-20℃~60℃ | ||
Normal Operating Temperature Range | 25℃ ± 5 ℃ | ||
Float charging Voltage | 13.6 to 13.8V DC/unit Average at 25℃ | ||
Equalization and Cycle Service | 14.4to 14.6V DC/unit Average at 25℃ | ||
Self Discharge | Front triminal batteries can be stored for more than 6 months at 25℃. Self-discharge ratio less than 3% per month at 25℃. Please charge batteries before using. | ||
Size | 410*109*293MM | 550*110*290MM | 550*125*317MM |
Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal |
Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper |
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.6V | 254 | 196 | 117 | 71.9 | 43.8 | 31.2 | 25.2 | 21.5 | 14.8 | 12.2 | 6.47 |
9.9V | 246 | 191 | 115 | 70.9 | 43.6 | 31.0 | 25.1 | 21.4 | 14.7 | 12.2 | 6.46 |
10.2V | 236 | 184 | 111 | 69.1 | 43.2 | 30.8 | 24.9 | 21.3 | 14.6 | 12.2 | 6.44 |
10.5V | 226 | 178 | 108 | 67.6 | 42.6 | 30.6 | 24.7 | 21.1 | 14.5 | 12.1 | 6.40 |
10.8V | 213 | 168 | 104 | 65.5 | 41.5 | 29.7 | 24.0 | 20.5 | 14.1 | 12.0 | 6.36 |
>Constant Power Discharge Characteristics(Watt,25ºC)
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.60V | 2741 | 2147 | 1313 | 820 | 508 | 367 | 297 | 255 | 176 | 146 | 77.7 |
9.90V | 2658 | 2096 | 1286 | 808 | 505 | 365 | 295 | 253 | 175 | 146 | 77.5 |
10.2V | 2549 | 2017 | 1247 | 787 | 500 | 362 | 293 | 251 | 174 | 145 | 77.3 |
10.5V | 2439 | 1950 | 1217 | 771 | 493 | 360 | 291 | 250 | 172 | 144 | 76.9 |
10.8V | 2302 | 1847 | 1172 | 747 | 480 | 349 | 282 | 242 | 167 | 143 | 76.3 |
>Warning
• Replacement of battery shall be performed as per following order. If failed, it may cause fire and explosion. Remove cable from negative terminal first.Connect cable to negative terminal last.
• When connect cable to battery, make sure not to get changed post of +and -. It may cause the damage of electronic components or fire.
• When ueing the battery ,handle with care,sulfuric acid may cause blindness or severe burn.
>Caution
• When moving battery, be careful not to drop the battery , which is heavy, Do not shake the battery with handle, if there is the handle, It may cause the injury.
• Do not shore the battery at the following places. High temperature and humidity. Being exposed to rain,snow, direct sunshine.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
80millions-120millions
Employee Number:
500~1000
Ecer Certification:
Site Member
SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD. "Established in 2012 ,but we start from 2009 ,So we have 10+years experience in lead acid battery. At the beginning we build the big professional team in the battery production ,So we know everything in the battery product... SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD. "Established in 2012 ,but we start from 2009 ,So we have 10+years experience in lead acid battery. At the beginning we build the big professional team in the battery production ,So we know everything in the battery product...
Get in touch with us
Leave a Message, we will call you back quickly!